Tested and certified in accordance with the European standard and guidelines for prison and detention cell doors, it features a robust design and offers no opportunities for suicide attempts.
The door was tested from both sides in the resistance level RC 4 (DIN EN 1627-1630):
- From the exterior side (corridor side, against forced entry respectively release attempts) and additionally
- From the interior side (cell side, against break out attempts).
Tested according to the guidelines for cell doors of the federal state of Saxony-Anhalt.
The test results in detail:
- At an edge load of 2 t – the deflection was < 3 mm and
- At a static load of 2.5 t – the deflection was < 6.5 mm and
- At a torsion load of 2.0 t – the deflection was < 4 mm: 1.3 t load / deflection <80 mm).
- Similarly, the door must be operable with a key from the corridor without further technical aids after 15 min. fire exposure inside the cell.
Supplementary equipment
Food hatch
- Robust steel construction that is flush fitted on the cell side. Two reinforced hinges also function as limiting stays. Food hatch lock available as an option.
Door viewer (standard)
Angle of vision up to 200°.
Tamper and vandalism-proof door viewer
Brief description:
- Angle of vision up to 150°.
- No screws installed on the cell side (tamper-proof).
- Operation on the corridor side by authorised personnel.
Benefits: 3 settings
- Blind setting (closed), inmates cannot tamper with the device from the cell side.
- Observation setting, noiseless opening from the corridor side, view of the entire room.
- Open setting, e.g. for passing through medicine and for cleaning if the viewer is dirty.
Security chain
Solid, robust security chain developed for extreme everyday use in prisons or by the police. The mounting plate is attached to the frame trim and the locking rail is mounted on the door leaf. The chain can also be hung on both sides if required.
Inspection window
The armored glass pane in accordance with DIN EN 356 can be integrated into the door leaf in different shapes and sizes up to the highest resistance class. An optional safety screen can be attached on the corridor side.
Fanlight
Video technology and lighting systems, for example, can be installed in the fanlight. It is secured on the cell side with flush-fitted armored glass in accordance with DIN EN 356.
Quick-release mechanism by means of sliding bolt or handle
- Quick-release function by means of sliding bolt: two solid sliding bolts made from steel flat secure the door as quickly as possible.
- Quick-release function by means of handle: easy, fast and reliable locking by means of lever bolt.
Vandalism-proof door status display
Protection against forced entry, bullets and explosion, also in different security classes, can be combined individually.
The S1es series offers, in combination with the Schüco series FWS, a flexible system solution, while the external aesthetic remain identical.
This clever and consistent facade system from SÄLZER and Schüco opens up a whole new dimension in reliably excellent facade design for architects, designers and builders:
- with maximum creative freedom
- with a uniform appearance
- with a wide range of insert units
- with a tailored combination of security levels
S1es-50/60 Semi-SG
- System basic depth min. – max.: 85 – 255 mm
- Face width: 50/60 mm
- Glass/panel thickness: 32 – 70 mm (S1es-50
- Semi-SG) bzw. 32 – 75 mm (S1es-60 Semi-SG)
- Installation angle: 90° – 105°
- Polygon facade angle (not for bullet resistance): 20°
- Skylight construction vert. incline min. – max.: No
- Skylight construction: No
- Drainage: Yes
- Drainage levels: 3
- Sun shading attachment: No
- Integrated sun shading: No
- Lightning protection: Yes
S1es-50/S1es-60
- System basic depth min. – max.: 85 – 255 mm, 22 mm, top profiles
- Face width: 50/60 mm
- Glass/panel thickness: 4 – 70 mm (S1es-50) bzw. 4 – 112 mm (S1es-60)
- Installation angle: 7° – 105°
- Polygon facade angle (not for bullet resistance): 20°
- Skylight construction vert. incline min. – max.: 7° – 90°
- Skylight construction: Yes
- Drainage: Yes
- Drainage levels: 3
- Sun shading attachment: Yes
- Integrated sun shading: Yes
- Lightning protection: Yes
Combined protection
S1es-50 Semi-SG
- Face width: 50 mm
Forced entry and break-out resistance
- According to DIN EN 1627-1630 up to RC4, glazing according to DIN EN 356 up to P6B/P7B.
S1es-60 Semi-SG
- Face width: 60 mm
Forced entry and break-out resistance
- According to DIN EN 1627-1630 up to RC4, tested on both sides (forced entry and break out resistant), glazing according to DIN EN 356 up to P6B/P7B.
Blast resistance
- Tested according to customer-specific requirements, e.g. with 500 kg explosives | distance 60 m. Classified: GSA 2 (Protection Level ”Very High”), ISO B (Hazard Rating ”No Hazard”).
Combined protection
S1es-50
- Face width: 50 mm
Forced entry and break-out resistance
- According to DIN EN 1627-1630 up to RC4, tested on both sides (forced entry and break out resistant), glazing according to DIN EN 356 up to P6B/P7B.
Bullet resistance
- Accoding to DIN 1522-1523 up to FB4-NS, glazing according DIN EN 1063 up to BR4-NS.
S1es-60
- Face width: 60 mm
Forced entry and break-out resistance
- According to DIN EN 1627-1630 up to RC5, tested on both sides (forced entry and break out resistant). Remarks on the glazing: in the high security class RC5 the glazing according to DIN EN 356, P7B, has to be replaced with more resistant glazing because they are only tested with axe blows. These P7B glazing cannot withstand attacks with the power tools used in these high forced entry class.
Bullet resistance
- Accoding to DIN 1522-1523 up to FB7-NS, glazing according DIN EN 1063 up to BR7-NS.
Blast resistance
- Tested according to customer-specific requirements, e.g. with 500 kg explosives | distance 28 m. Project-specific verifications with long pressure duration according requirements for the petrochemical industry. Project-specific verifications according to DIN EN 13123-1 and DIN EN 13124-1 up EPR4. Classified: GSA 2 (Protection Level ”Very High”), ISO B (Hazard Rating ”No Hazard”).